WATER & WASTE WATER TREATMENT CONSULTANTS, COMPONENTS, & EQUIPMENTS
DEAR SIR,
We take pleasure in introducing ourselves as professionals involved in the field of water and waste water treatment engineering. Our set up was incorporated to market various water treatment equipments, chemicals and under take contracts for turnkey jobs as well as detailed engineering and design of water and waste water treatment equipments. We provide total consultancy for water treatment engineering, design, supply, installation, commissioning and operation of the plant. We have wide engineering capability in processing, sugar industry, oil refining, pharmaceuticals and other chemical processing industries.
Since the start of the business the primary focus has been on the total customer service and customer satisfaction through constant up gradation of technologies and commitment for quality. In the process, we have become a company with a will to accomplish innovative and challenging tasks. Our activities are no longer confined to water treatment plant manufacturing, but have extended in the design, manufacture, erection and commissioning of waste water treatment plant for reuse, membrane based equipment for product recovery and custom made specialized process equipment.
We would be pleased to be associated with you and hence would request you to give us an opportunity to serve your cause.
Looking forward to our getting together.
Thanking you, assuring you of our best services, we remain.
Yours faithfully,
V.ANAND TIRTHA.
NEW NO.5, DANDAPANI STREET, T. NAGAR, CHENNAI- 600017.
TELEFAX: 4341917, 2456593.
E-MAIL. Kdossin@yahoo.com
A HOUSE FOR COMPLETE WATER AND WASTE WATER COMPONENTS, EQUIPMENTS & SYSTEMS
Dear Sir,
We thank, you very much for the patronage and co-operation extended to us all these years. We take pleasure to inform to all O.E.M , dealers & end users, that, this is a single house where all components and equipments are available for easy purchase and quick Installation at competitive price for today's market condition, and quality is assured for all items.
We here by furnish below the list of components and equipments manufactured and marketed by us.
FILTERS [sand, carbon, dual media]
FILTER UNDER BED MEDIA
ACTIVATED CARBON
ANTHRACITE
DEFERROUS SAND
FLANGE GASKETS |
 |
ION EXCHANGE PLANTS
SOFTNERS
D M PLANTS [standard plants]
M.B.PLANTS
ION EXCHANGE RESINS
[softener, cation, anion, mixed bed]
PP STRAINER
EJECTORS
CONDUCTIVITY METERS
PALL RINGS
RESIN TRAPS
MIDDLE COLLECTORS
|
 |
REVERSE OSMOSIS SYSTEM
RO MEMBRANE ALL SIZE [stockiest]
DOMESTIC RO SYSTEM
DOMESTIC RO MEMBRANE
DOMESTIC RO PUMP&TRANSFORMER
DOMESTIC RO MEMBRANE HOUSING
ALL SIZE COMMERCIAL MEMBRANE
[2540, 4040, brackish low energy & tap water]
RO MEMBRANE HOUSING [S.S. & composite upto 50 bar]
RO MEMBRANE CLEANING CHEMICAL [imported]
HIGH PRESSURE PUMPS [imported & indigenous upto 60 bar]
BRINE SEAL
ORINGS |
CONNECTORS
END CAPS
P.P CATRIDGE FILTER HOUSING 10" & 20"
P.P WOUND CATRIDGE
SPUN BOUND CATRIDGE
CARBON CATRIDGE
U.V.STERILIZER
OZONATER
DOSING PUMPS INDIGENOUS
ROTO METERS
TDS METER
PH METER |
EFFLUENT / SEWAGE TREATMENT PLANTS
TREASURY TREATMENT FILTERS
AERATORS FIXED, FLOATING, DIFFUSED
CLARIFIERS[all sizes]
THICKNERS |
LAMELLA CLARIFIER
FILTER PRESS PP
ELECTRO CHLORINATOR |
ALL THE ABOVE ITEMS ARE SOLD IN LOOSE ALSO.
THE CHOICE FOR QUALITY,ACCURACY AND DURABILITY RO HIGH PRESSURE PUMP
High pressure triplexpump for brakish and sea water. 100 bar

ROBUST DESIGN HIGH PRESSURE TRIPLEX PUMP FOR REVERSE OSMOSIS SYSTEM TO FEED RAW WATER INTO MEMBRANE UNDER GREAT PRESSURE.THESE PUMPS ARE 80% TO 90% ENERGY EFFICIENT FOR TO DAY'S COST CONSCIOUS. THESE PUMPS REQUIRE SIMPLE MAINTENANCE, ALL PARTS ARE EASILY ACCESSIBLE.
Construction features
pulley, belt operated,flexi joint
Plunger sealed Single drive shaft operation
Pump body in cast iron
Heavy duty roller bearing
Plunger in stainless steel and oxide ceramic
|
Hardened crank shaft pulsation dampener* [these pumps are designed to international standard and aimed to minimize pulsation effect by internal arrangement]
Application
Reverse osmosis system feed [tap,brakish,sea water]
High pessure cleaning
Hydro testing
Boiler feed Many more.
Package Comes in completely assembled with tefc motor, pulley,pulsation dampener, ms frame, couplings,pressure relief valve,belt,glycerine filled pressure gauge
.*performance indicated are based on 95% volumetric efficiency. Pressure indicated at maximum discharge pressure. Never exceed specified rpm, pump should never run without pressure relief,safety valve. |
COMPOSITE REVERSE OSMOSIS PRESSURE VESSEL UPTO 700 PSI. CIRCLIP MODEL
INDIGINEOUSLY DEVELOPED STATE OF ART HIGH PRESSURE REVERSE OSMOSIS HOUSING IN COMPOSITE MATERIAL AND STAINLESS STEEL. ALL PRESSURE VESSELS ARE INDIVIUALLY TESTED TO ITS MAXIMUM PRESSURE AND CERTIFIED. AVAILABLE IN STAINLESS STEEL WITH SIDEPORT FACILITY UPTO A MAXIMUM PRESSURE OF 700PSI. *THE DESIGN OF ENDCAPS ENABLES EASY DISMANTLING AND REMOVING EVEN BY UNSKILLED PERSON AS IT IS STAINLESS STEEL EMBEDED.[*this design overcomes the imported end cap's threadworn-out frequently]ALL CIRCLIPS ARE TENSILE TESTED AND PLATED.
| PRESSURE VESSELS |
MATERIAL |
FACILITY |
MAX PRESS |
| 4040 SINGLE ELEMENT |
COMPOSITE |
END PORT |
40BAR |
| 4080 DOUBLE ELEMENT |
COMPOSITE |
END PORT |
40BAR |
| 4040 SINGLE ELEMENT |
SS |
SIDE/END |
50BAR |
| 4080 DOUBLE ELEMENT |
SS |
SIDE/END |
50BAR |
PACKAGE: SUPPLIED AS PRESSURE VESSEL,END CAPS[BOTH ENDS] WITH O RING,CIRCLIP,SILICON GREASE.
FREE FLOW. CLEAN
MESSAGE FOR DESALINATION PROCESS
FEC DS3 MEMBRANE CLEANING CHEMICAL FOR IN ORGANICS. LOW PH FORMULATION, DESIGNED SPECIALLY TO REMOVE METAL HYDROXIDE,CALCIUM CARBONATE SALTS AND SIMILAR SCALES FROM POLYSUFONE, POLYAMIDE AND TFC MEMBRANE SURFACES. HIGHLY ADVANCED POWDER FORM HAS FOLLOWING FEATURES.
- LOW PH 3. [these replace strong acids and hazardous solvents]
- THEY ARE NON-TOXIC AND USER FREINDLY.
- COMES IN POWDER FORM CONCENTRATED AND ECONOMICAL.
- CONTAINS NO SURFACTANTS AND QUICKLY RINSED.
- HAS ORGANIC ACID BASE,DETERGANT BUILDERS ANDCHELATING AGENTS.
- LEAVES NO INTERFERE RESIDUE IN THE SYSTEM.
- LESS CONSUMPTION OF CHEMICALS. [recommended 30gm/lt]
DIRECTION OF USE
- Thoroughly check tanks, micron filter,[change if necessary] hose and piping.
- Fill up ro product water in the tank.
- Dissolve ffc ds3 30gm/lt of water to the tank capacity.
- Maintain temperature [if necessary heat the chemical] as recommended by the membrane manufacturer.
- Circulate the cleaning solution under low pressure through the membrane in the feed direction for one hour or flow rate as recommended by the membrane manufacturer.
If heavy fouling occurs do not recirculate the cleaning solution for more cycles discard the entire chemical to prevent from deposition of solids in the membrane.
GENERAL GUIDELINES FOR MEMBRANE CLEANING
MEMBRANE SIZE (inches) |
NO OF MEMBRANE |
MINIMUM FLOW RATE (lts/min) |
2
2
2
4
4
4
4
4
8
8
8 |
1
2
4
1
2
4
6
8
1
3
5 |
6
13
23
9
16
35
55
76
16
50
80 |
After sufficient rinsing return the system to service. It is advised to clean the membrane by both chemicals for good result followed by one after other with intermittent flushing.
PACKING :
REPACKED IN 100,250 GMS, 1KG, 5 KG.
HANDLING :
WEAR SAFETY GLOVES, GOOGLES, RESIPRATOR. RINSE WITH PLENTY OF WATER.
FREE FLOW. CLEAN
MESSAGE FOR DESALINATION PROCESS
FEC DS11 MEMBRANE CLEANING CHEMICAL FOR ORGANICS. HIGH PH FORMULATION, DESIGNED SPECIALLY TO REMOVE ORGANICS, SILT AND OTHER PARTICULATE DEPOSITION FROM POLYAMIDE, POLYSULFONE AND TFC MEMBRANE SURFACES. HIGHLY ADVANCED POWDER FORM HAS FOLLOWING FEATURES.
- MODIFIED PH 3. [these replace strong soda and hazardous solvents]
- THEY ARE NON-TOXIC AND USER FREINDLY.
- COMES IN POWDER FORM CONCENTRATED AND ECONOMICAL.
- CONTAINS NO SURFACTANTS AND QUICKLY RINSED.
- HAS ALKALINE BASE,DETERGANT BUILDERS AND CHELATING AGENTS.
- LEAVES NO INTERFERE RESIDUE IN THE SYSTEM.
- LESS CONSUMPTION OF CHEMICALS. [recommended 30gm/lt]
DIRECTION OF USE
- Thoroughly check tanks, micron filter,[change if necessary] hose and piping.
- Fill up ro product water in the tank.
- Dissolve ffc ds11 30gm/lt of water to the tank capacity.
- Maintain temperature [if necessary heat the chemical] as recommended by the membrane manufacturer.
- Circulate the cleaning solution under low pressure through the membrane in the feed direction for one hour or flow rate as recommended by the membrane manufacturer.
If heavy fouling occurs do not recirculate the cleaning solution for more cycles discard the entire chemical to prevent from deposition of solids in the membrane.
GENERAL GUIDELINES FOR MEMBRANE CLEANING
MEMBRANE SIZE (inches) |
NO OF MEMBRANE |
MINIMUM FLOW RATE (lts/min) |
2
2
2
4
4
4
4
4
8
8
8 |
1
2
4
1
2
4
6
8
1
3
5 |
6
13
23
9
16
35
55
76
16
50
80 |
After sufficient rinsing return the system to service. It is advised to clean the membrane by both chemicals for good result followed by one after other with intermittent flushing.
PACKING :
REPACKED IN 100,250 GMS, 1KG, 5 KG.
HANDLING :
WEAR SAFETY GLOVES, GOOGLES, RESIPRATOR. RINSE WITH PLENTY OF WATER.
|